Time Series and Attributes Controls
Run Rules
This page describes the rules of the time series and attributes controls.
You can enable/disable as well as
add custom rules. The time series controls are:
The rules for the time series controls are located at the series and
limit range level. The rules for the attributes series controls
are located at the series level and the controls are:
A rule of the controls is of the following type:
The first step is to include the necessary namespaces
for the controls and add a new time series or add a new attributes series.
Built-in Rules
The table below describes the rules that are built-in to the controls. These
rules may be modifed, such as changing the limit and run/fail lengths, or
new rules may be added.
|
| Rule Name |
Rule Description |
Upper Limit |
Lower Limit |
Run Length |
Fail Length |
| Western Electric Rule #1 |
One point above or below the control limits |
UCL |
LCL |
1 |
1 |
| Western Electric Rule #2 |
Run above or below centerline |
- |
CL |
7 |
7 |
| Western Electric Rule #3 |
Trend |
- |
- |
7 |
7 |
| Western Electric Rule #4 |
Cyclic |
- |
- |
14 |
14 |
| Western Electric Rule #5 |
Two out of three in Zone A or beyond |
2 Sigma |
-2 Sigma |
3 |
2 |
| Western Electric Rule #6 |
Four out of five in zone B or beyond |
1 Sigma |
-1 Sigma |
5 |
4 |
| Western Electric Rule #7 |
Fifteen consecutive points between +/- 1 sigma |
1 Sigma |
-1 Sigma |
15 |
15 |
| Western Electric Rule #8 |
No points between +/- 1 sigma |
1 Sigma |
-1 Sigma |
8 |
0 |
| Western Electric Rule #9 |
One point outside specification limits |
USL |
LSL |
1 |
1 |
|
Events
When a rule fails, an event is fired. The event can be captured at the control or
series level. The event is of the following type: